Oracle® Database PL/SQL Language Reference 11g Release 2 (11.2) Part Number E25519-05 |
|
|
PDF · Mobi · ePub |
Every PL/SQL constant, variable, parameter, and function return value has a data type that determines its storage format and its valid values and operations.
This chapter explains scalar data types, which store values with no internal components. For information about composite data types, see Chapter 5, "PL/SQL Collections and Records".
A scalar data type can have subtypes. A subtype is a data type that is a subset of another data type, which is its base type. A subtype has the same valid operations as its base type. A data type and its subtypes comprise a data type family.
PL/SQL predefines many types and subtypes in the package STANDARD
and lets you define your own subtypes.
The PL/SQL scalar data types are:
The SQL data types
BOOLEAN
PLS_INTEGER
BINARY_INTEGER
REF
CURSOR
, explained in "Cursor Variables"
User-defined subtypes
See Also:
"CREATE TYPE Statement" for information about creating schema-level user-defined data types
Appendix E, "PL/SQL Predefined Data Types" for the predefined PL/SQL data types and subtypes, grouped by data type family
The PL/SQL data types include the SQL data types. For information about the SQL data types, see Oracle Database SQL Language Reference—all information there about data types and subtypes, data type comparison rules, data conversion, literals, and format models applies to both SQL and PL/SQL, except as noted here:
Additional PL/SQL Constants for BINARY_FLOAT and BINARY_DOUBLE
Additional PL/SQL Subtypes of BINARY_FLOAT and BINARY_DOUBLE
Unlike SQL, PL/SQL lets you declare variables, to which the following topics apply:
The SQL data types listed in Table 3-1 have different maximum sizes in PL/SQL and SQL.
Table 3-1 Data Types with Different Maximum Sizes in PL/SQL and SQL
Data Type | Maximum Size in PL/SQL | Maximum Size in SQL |
---|---|---|
|
32,767 bytes |
2,000 bytes |
|
32,767 bytes |
2,000 bytes |
|
32,767 bytes |
2,000 bytes |
|
32,767 bytes |
4,000 bytes |
|
32,767 bytes |
4,000 bytes |
|
32,760 bytes |
2 gigabytes (GB) - 1 |
|
32,760 bytes |
2 GB |
|
128 terabytes (TB) |
(4 GB - 1) * |
|
128 TB |
(4 GB - 1) * |
|
128 TB |
(4 GB - 1) * |
Footnote 1 When specifying the maximum size of a value of this data type in PL/SQL, use an integer literal (not a constant or variable) whose value is in the range from 1 through 32,676.
Footnote 2 Supported only for backward compatibility with existing applications.
The SQL data types BINARY_FLOAT
and BINARY_DOUBLE
represent single-precision and double-precision IEEE 754-format floating-point numbers, respectively.
BINARY_FLOAT
and BINARY_DOUBLE
computations do not raise exceptions, so you must check the values that they produce for conditions such as overflow and underflow by comparing them to predefined constants (for examples, see Oracle Database SQL Language Reference). PL/SQL has more of these constants than SQL does.
Table 3-2 lists and describes the predefined PL/SQL constants for BINARY_FLOAT
and BINARY_DOUBLE
, and identifies those that SQL also defines.
Table 3-2 Predefined PL/SQL BINARY_FLOAT and BINARY_DOUBLE ConstantsFoot 1
Constant | Description |
---|---|
|
|
|
Single-precision positive infinity |
|
Maximum normal |
|
Minimum normal |
|
Maximum subnormal |
|
Minimum subnormal |
|
|
|
Double-precision positive infinity |
|
Maximum normal |
|
Minimum normal |
|
Maximum subnormal |
|
Minimum subnormal |
Footnote 1 SQL also predefines this constant.
PL/SQL predefines these subtypes:
Each subtype has the same range as its base type and has a NOT
NULL
constraint (explained in "NOT NULL Constraint").
If you know that a variable will never have the value NULL
, declare it as SIMPLE_FLOAT
or SIMPLE_DOUBLE
, rather than BINARY_FLOAT
or BINARY_DOUBLE
. Without the overhead of checking for nullness, the subtypes provide significantly better performance than their base types. The performance improvement is greater with PLSQL_CODE_TYPE='NATIVE'
than with PLSQL_CODE_TYPE='INTERPRETED'
(for more information, see "Use Data Types that Use Hardware Arithmetic").
If the value that you assign to a character variable is longer than the maximum size of the variable, an error occurs. For example:
DECLARE c VARCHAR2(3 CHAR); BEGIN c := 'abc '; END; /
Result:
DECLARE * ERROR at line 1: ORA-06502: PL/SQL: numeric or value error: character string buffer too small ORA-06512: at line 4
Similarly, if you insert a character variable into a column, and the value of the variable is longer than the defined width of the column, an error occurs. For example:
DROP TABLE t; CREATE TABLE t (c CHAR(3 CHAR)); DECLARE s VARCHAR2(5 CHAR) := 'abc '; BEGIN INSERT INTO t(c) VALUES(s); END; /
Result:
BEGIN * ERROR at line 1: ORA-12899: value too large for column "HR"."T"."C" (actual: 5, maximum: 3) ORA-06512: at line 4
To strip trailing blanks from a character value before assigning it to a variable or inserting it into a column, use the RTRIM
function, explained in Oracle Database SQL Language Reference. For example:
DECLARE c VARCHAR2(3 CHAR); BEGIN c := RTRIM('abc '); INSERT INTO t(c) VALUES(RTRIM('abc ')); END; /
Result:
PL/SQL procedure successfully completed.
The maximum size of a CHAR
or VARCHAR2
variable is 32,767 bytes, whether you specify the maximum size in characters or bytes. The maximum number of characters in the variable depends on the character set type and sometimes on the characters themselves:
Character Set Type | Maximum Number of Characters |
---|---|
Single-byte character set | 32,767 |
n-byte fixed-width multibyte character set (for example, AL16UTF16) | FLOOR(32,767/ n ) |
n-byte variable-width multibyte character set with character widths between 1 and n bytes (for example, JA16SJIS or AL32UTF8) | Depends on characters themselves—can be anything from 32,767 (for a string containing only 1-byte characters) through FLOOR(32,767/ n ) (for a string containing only n-byte characters). |
When declaring a CHAR
or VARCHAR2
variable, to ensure that it can always hold n characters in any multibyte character set, declare its length in characters—that is, CHAR(
n
CHAR)
or VARCHAR2(
n
CHAR)
, where n does not exceed FLOOR(32767/4)
= 8191.
See Also:
Oracle Database Globalization Support Guide for information about Oracle Database character set supportCHAR
and VARCHAR2
data types differ in:
The CHAR
data type has one predefined subtype in both PL/SQL and SQL—CHARACTER
.
The VARCHAR2
data type has one predefined subtype in both PL/SQL and SQL, VARCHAR
, and an additional predefined subtype in PL/SQL, STRING
.
Each subtype has the same range of values as its base type.
Note:
In a future PL/SQL release, to accommodate emerging SQL standards,VARCHAR
might become a separate data type, no longer synonymous with VARCHAR2
.For a CHAR
variable, PL/SQL allocates at compile time enough memory for the maximum size.
For a VARCHAR2
variable, memory allocation depends on maximum size:
If the maximum size is less than 4,000 bytes, PL/SQL allocates at compile time enough memory for the maximum size.
If the maximum size is 4,000 bytes or more, PL/SQL allocates at run time enough memory for the actual value.
For example, suppose that variables a
and b
are declared as follows:
a VARCHAR2(3999); b VARCHAR2(4000);
If you assign the same 500-byte value to both variables, PL/SQL allocates 3,999 bytes for a
at compile time and 500 bytes for b
at run time.
Thus, PL/SQL optimizes smaller VARCHAR2
variables for performance and larger ones for efficient memory use.
The value that you assign to a variable is shorter than the maximum size of the variable.
The value that you insert into a column is shorter than the defined width of the column.
The value that you retrieve from a column into a variable is shorter than the maximum size of the variable.
If the data type of the receiver is CHAR
, PL/SQL blank-pads the value to the maximum size. Information about trailing blanks in the original value is lost.
If the data type of the receiver is VARCHAR2
, PL/SQL neither blank-pads the value nor strips trailing blanks. Character values are assigned intact, and no information is lost.
In Example 3-1, both the CHAR
variable and the VARCHAR2
variable have the maximum size of 10 characters. Each variable receives a five-character value with one trailing blank. The value assigned to the CHAR
variable is blank-padded to 10 characters, and you cannot tell that one of the six trailing blanks in the resulting value was in the original value. The value assigned to the VARCHAR2
variable is not changed, and you can see that it has one trailing blank.
Example 3-1 CHAR and VARCHAR2 Blank-Padding Difference
DECLARE first_name CHAR(10 CHAR); last_name VARCHAR2(10 CHAR); BEGIN first_name := 'John '; last_name := 'Chen '; DBMS_OUTPUT.PUT_LINE('*' || first_name || '*'); DBMS_OUTPUT.PUT_LINE('*' || last_name || '*'); END; /
Result:
*John * *Chen *
The SQL rules for comparing character values apply to PL/SQL character variables. Whenever one or both values in the comparison have the data type VARCHAR2
or NVARCHAR2
, nonpadded comparison semantics apply; otherwise, blank-padded semantics apply. For more information, see Oracle Database SQL Language Reference.
Note:
Oracle supports theLONG
and LONG
RAW
data types only for backward compatibility with existing applications. For new applications:
Instead of LONG
, use VARCHAR2(32760)
, BLOB
, CLOB
or NCLOB
.
Instead of LONG
RAW
, use BLOB
.
You can insert any LONG
value into a LONG
column. You can insert any LONG
RAW
value into a LONG
RAW
column. You cannot retrieve a value longer than 32,760 bytes from a LONG
or LONG
RAW
column into a LONG
or LONG
RAW
variable.
You can insert any CHAR
or VARCHAR2
value into a LONG
column. You cannot retrieve a value longer than 32,767 bytes from a LONG
column into a CHAR
or VARCHAR2
variable.
You can insert any RAW
value into a LONG
RAW
column. You cannot retrieve a value longer than 32,767 bytes from a LONG
RAW
column into a RAW
variable.
See Also:
"Trigger LONG and LONG RAW Data Type Restrictions" for restrictions onLONG
and LONG
RAW
data types in triggersWhen you retrieve a rowid into a ROWID
variable, use the ROWIDTOCHAR
function to convert the binary value to a character value. For information about this function, see Oracle Database SQL Language Reference.
To convert the value of a ROWID
variable to a rowid, use the CHARTOROWID
function, explained in Oracle Database SQL Language Reference. If the value does not represent a valid rowid, PL/SQL raises the predefined exception SYS_INVALID_ROWID
.
To retrieve a rowid into a UROWID
variable, or to convert the value of a UROWID
variable to a rowid, use an assignment statement; conversion is implicit.
Note:
UROWID
is a more versatile data type than ROWID
, because it is compatible with both logical and physical rowids.
When you update a row in a table compressed with Hybrid Columnar Compression (HCC), the ROWID
of the row changes. HCC, a feature of certain Oracle storage systems, is described in Oracle Database Concepts.
See Also:
Oracle Database PL/SQL Packages and Types Reference for information about theDBMS_ROWID
package, whose subprograms let you create and return information about ROWID
values (but not UROWID
values)The PL/SQL data type BOOLEAN
stores logical values, which are the Boolean values TRUE
and FALSE
and the value NULL
. NULL
represents an unknown value.
The syntax for declaring an BOOLEAN
variable is:
variable_name BOOLEAN
The only value that you can assign to a BOOLEAN
variable is a BOOLEAN
expression. For details, see "BOOLEAN Expressions".
Because SQL has no data type equivalent to BOOLEAN
, you cannot:
Assign a BOOLEAN
value to a database table column
Select or fetch the value of a database table column into a BOOLEAN
variable
Use a BOOLEAN
value in a SQL statement, SQL function, or PL/SQL function invoked from a SQL statement
You cannot pass a BOOLEAN
value to the DBMS_OUTPUT
.PUT
or DBMS_OUTPUT
.PUTLINE
subprogram. To print a BOOLEAN
value, use an IF
or CASE
statement to translate it to a character value (for information about these statements, see "Conditional Selection Statements").
In Example 3-2, the procedure accepts a BOOLEAN
parameter and uses a CASE
statement to print Unknown
if the value of the parameter is NULL
, Yes
if it is TRUE
, and No
if it is FALSE
.
Example 3-2 Printing BOOLEAN Values
CREATE PROCEDURE print_boolean (b BOOLEAN) AS BEGIN CASE WHEN b IS NULL THEN DBMS_OUTPUT.PUT_LINE('Unknown'); WHEN b THEN DBMS_OUTPUT.PUT_LINE('Yes'); WHEN NOT b THEN DBMS_OUTPUT.PUT_LINE('No'); END CASE; END; / BEGIN print_boolean(TRUE); print_boolean(FALSE); print_boolean(NULL); END; /
Result:
Yes No Unknown
The PL/SQL data types PLS_INTEGER
and BINARY_INTEGER
are identical. For simplicity, this document uses PLS_INTEGER
to mean both PLS_INTEGER
and BINARY_INTEGER
.
The PLS_INTEGER
data type stores signed integers in the range -2,147,483,648 through 2,147,483,647, represented in 32 bits.
The PLS_INTEGER
data type has these advantages over the NUMBER
data type and NUMBER
subtypes:
PLS_INTEGER
values require less storage.
PLS_INTEGER
operations use hardware arithmetic, so they are faster than NUMBER
operations, which use library arithmetic.
For efficiency, use PLS_INTEGER
values for all calculations in its range.
A calculation with two PLS_INTEGER
values that overflows the PLS_INTEGER
range raises an overflow exception, even if you assign the result to a NUMBER
data type (as in Example 3-3). For calculations outside the PLS_INTEGER
range, use INTEGER
, a predefined subtype of the NUMBER
data type (as in Example 3-4).
Example 3-3 PLS_INTEGER Calculation Raises Overflow Exception
DECLARE p1 PLS_INTEGER := 2147483647; p2 PLS_INTEGER := 1; n NUMBER; BEGIN n := p1 + p2; END; /
Result:
DECLARE
*
ERROR at line 1:
ORA-01426: numeric overflow
ORA-06512: at line 6
Example 3-4 Preventing Example 3-3 Overflow
DECLARE
p1 PLS_INTEGER := 2147483647;
p2 INTEGER := 1;
n NUMBER;
BEGIN
n := p1 + p2;
END;
/
Result:
PL/SQL procedure successfully completed.
Table 3-3 lists the predefined subtypes of the PLS_INTEGER
data type and describes the data they store.
Table 3-3 Predefined Subtypes of PLS_INTEGER Data Type
Data Type | Data Description |
---|---|
Nonnegative |
|
Nonnegative |
|
Positive |
|
Positive |
|
|
|
|
|
Footnote 1 For information about the NOT
NULL
constraint, see "NOT NULL Constraint".
PLS_INTEGER
and its subtypes can be implicitly converted to these data types:
CHAR
VARCHAR2
NUMBER
LONG
All of the preceding data types except LONG
, and all PLS_INTEGER
subtypes, can be implicitly converted to PLS_INTEGER
.
A PLS_INTEGER
value can be implicitly converted to a PLS_INTEGER
subtype only if the value does not violate a constraint of the subtype. For example, casting the PLS_INTEGER
value NULL
to the SIMPLE_INTEGER
subtype raises an exception, as Example 3-5 shows.
SIMPLE_INTEGER
is a predefined subtype of the PLS_INTEGER
data type that has the same range as PLS_INTEGER
and has a NOT
NULL
constraint (explained in "NOT NULL Constraint"). It differs significantly from PLS_INTEGER
in its overflow semantics.
If you know that a variable will never have the value NULL
or need overflow checking, declare it as SIMPLE_INTEGER
rather than PLS_INTEGER
. Without the overhead of checking for nullness and overflow, SIMPLE_INTEGER
performs significantly better than PLS_INTEGER
.
If and only if all operands in an expression have the data type SIMPLE_INTEGER
, PL/SQL uses two's complement arithmetic and ignores overflows. Because overflows are ignored, values can wrap from positive to negative or from negative to positive; for example:
230 + 230 = 0x40000000 + 0x40000000 = 0x80000000 = -231
-231 + -231 = 0x80000000 + 0x80000000 = 0x00000000 = 0
For example, this block runs without errors:
DECLARE
n SIMPLE_INTEGER := 2147483645;
BEGIN
FOR j IN 1..4 LOOP
n := n + 1;
DBMS_OUTPUT.PUT_LINE(TO_CHAR(n, 'S9999999999'));
END LOOP;
FOR j IN 1..4 LOOP
n := n - 1;
DBMS_OUTPUT.PUT_LINE(TO_CHAR(n, 'S9999999999'));
END LOOP;
END;
/
Result:
+2147483646 +2147483647 -2147483648 -2147483647 -2147483648 +2147483647 +2147483646 +2147483645 PL/SQL procedure successfully completed.
If an expression has both SIMPLE_INTEGER
and other operands, PL/SQL implicitly converts the SIMPLE_INTEGER
values to PLS_INTEGER
NOT
NULL
.
The PL/SQL compiler issues a warning when SIMPLE_INTEGER
and other values are mixed in a way that might negatively impact performance by inhibiting some optimizations.
Integer literals in the SIMPLE_INTEGER
range have the data type SIMPLE_INTEGER
. However, to ensure backward compatibility, when all operands in an arithmetic expression are integer literals, PL/SQL treats the integer literals as if they were cast to PLS_INTEGER
.
PL/SQL lets you define your own subtypes. The base type can be any scalar PL/SQL type, including a previously defined user-defined subtype.
Note:
The information in this topic applies to both user-defined subtypes and the predefined subtypes listed in Appendix E, "PL/SQL Predefined Data Types".Subtypes can:
Provide compatibility with ANSI/ISO data types
Show the intended use of data items of that type
Detect out-of-range values
An unconstrained subtype has the same set of values as its base type, so it is only another name for the base type. Therefore, unconstrained subtypes of the same base type are interchangeable with each other and with the base type. No data type conversion occurs.
To define an unconstrained subtype, use this syntax:
SUBTYPE subtype_name IS base_type
For information about subtype_name
and base_type
, see subtype_definition.
An example of an unconstrained subtype, which PL/SQL predefines for compatibility with ANSI, is:
SUBTYPE "DOUBLE PRECISION" IS FLOAT
In Example 3-6, the unconstrained subtypes Balance
and Counter
show the intended uses of data items of their types.
Example 3-6 User-Defined Unconstrained Subtypes Show Intended Use
DECLARE SUBTYPE Balance IS NUMBER; checking_account Balance(6,2); savings_account Balance(8,2); certificate_of_deposit Balance(8,2); max_insured CONSTANT Balance(8,2) := 250000.00; SUBTYPE Counter IS NATURAL; accounts Counter := 1; deposits Counter := 0; withdrawals Counter := 0; overdrafts Counter := 0; PROCEDURE deposit ( account IN OUT Balance, amount IN Balance ) IS BEGIN account := account + amount; deposits := deposits + 1; END; BEGIN NULL; END; /
A constrained subtype has only a subset of the values of its base type.
If the base type lets you specify size, precision and scale, or a range of values, then you can specify them for its subtypes. The subtype definition syntax is:
SUBTYPE subtype_name IS base_type { precision [, scale ] | RANGE low_value .. high_value } [ NOT NULL ]
Otherwise, the only constraint that you can put on its subtypes is NOT
NULL
(described in "NOT NULL Constraint"):
SUBTYPE subtype_name IS base_type [ NOT NULL ]
Note:
The only base types for which you can specify a range of values arePLS_INTEGER
and its subtypes (both predefined and user-defined).In Example 3-7, the constrained subtype Balance
detects out-of-range values.
Example 3-7 User-Defined Constrained Subtype Detects Out-of-Range Values
DECLARE SUBTYPE Balance IS NUMBER(8,2); checking_account Balance; savings_account Balance; BEGIN checking_account := 2000.00; savings_account := 1000000.00; END; /
Result:
DECLARE
*
ERROR at line 1:
ORA-06502: PL/SQL: numeric or value error: number precision too large
ORA-06512: at line 9
A constrained subtype can be implicitly converted to its base type, but the base type can be implicitly converted to the constrained subtype only if the value does not violate a constraint of the subtype (see Example 3-5).
A constrained subtype can be implicitly converted to another constrained subtype with the same base type only if the source value does not violate a constraint of the target subtype.
In Example 3-8, the three constrained subtypes have the same base type. The first two subtypes can be implicitly converted to the third subtype, but not to each other.
Example 3-8 Implicit Conversion Between Constrained Subtypes with Same Base Type
DECLARE SUBTYPE Digit IS PLS_INTEGER RANGE 0..9; SUBTYPE Double_digit IS PLS_INTEGER RANGE 10..99; SUBTYPE Under_100 IS PLS_INTEGER RANGE 0..99; d Digit := 4; dd Double_digit := 35; u Under_100; BEGIN u := d; -- Succeeds; Under_100 range includes Digit range u := dd; -- Succeeds; Under_100 range includes Double_digit range dd := d; -- Raises error; Double_digit range does not include Digit range END; /
Result:
DECLARE * ERROR at line 1: ORA-06502: PL/SQL: numeric or value error ORA-06512: at line 12
See Also:
"Formal and Actual Subprogram Parameters" for information about subprogram parameters of constrained data typesIf two subtypes have different base types in the same data type family, then one subtype can be implicitly converted to the other only if the source value does not violate a constraint of the target subtype. (For the predefined PL/SQL data types and subtypes, grouped by data type family, see Appendix E, "PL/SQL Predefined Data Types".)
In Example 3-9, the subtypes Word
and Text
have different base types in the same data type family. The first assignment statement implicitly converts a Word
value to Text
. The second assignment statement implicitly converts a Text
value to Word
. The third assignment statement cannot implicitly convert the Text
value to Word
, because the value is too long.
Example 3-9 Implicit Conversion Between Subtypes with Base Types in Same Family
DECLARE SUBTYPE Word IS CHAR(6); SUBTYPE Text IS VARCHAR2(15); verb Word := 'run'; sentence1 Text; sentence2 Text := 'Hurry!'; sentence3 Text := 'See Tom run.'; BEGIN sentence1 := verb; -- 3-character value, 15-character limit verb := sentence2; -- 5-character value, 6-character limit verb := sentence3; -- 12-character value, 6-character limit END; /
Result:
DECLARE * ERROR at line 1: ORA-06502: PL/SQL: numeric or value error: character string buffer too small ORA-06512: at line 13